電動工具 Atlas Copco 8432084561のPDF 製品取扱説明書をオンラインで閲覧またはダウンロードできます。Atlas Copco 8432084561 16 ページ。 Handheld transducerized
ETD MT41-100-I06
Service
Preventing ESD Problems
The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.
Maintenance Instructions
Service Recommendations
Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guide-
lines:
■
Clean appropriate parts accurately
■
Replace any defective or worn parts
Preventive maintenance
Recommended interval between actions:
Valid at normal usage of the tool at a load up to 70% of maximum torque.
Service should only be carried out by trained technician following provided service instructions and
using original Atlas Copco spare parts.
Interval
1.500.000 cycles or 1 year
1.500.000 cycles
3.000.000 cycles
3.000.000 cycles
Calibration recommendations
According to MT Calibration Configuration Manual 9839 0812, the calibration is needed when the
following parts are replaced:
■
Drive unit
■
Motor
■
Front part
■
Trigger module
EN
© Atlas Copco Industrial Technique AB - 9839 1064 01
Action
Calibrate the tool
Exchange bit grounding
Exchange front part
Exchange motor
Service