Atlas Copco 8432084561 제품 지침 - 페이지 13

{카테고리_이름} Atlas Copco 8432084561에 대한 제품 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Atlas Copco 8432084561 16 페이지. Handheld transducerized

Atlas Copco 8432084561 제품 지침
ETD MT41-100-I06

Service

Preventing ESD Problems

The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.

Maintenance Instructions

Service Recommendations

Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guide-
lines:
Clean appropriate parts accurately
Replace any defective or worn parts

Preventive maintenance

Recommended interval between actions:
Valid at normal usage of the tool at a load up to 70% of maximum torque.
Service should only be carried out by trained technician following provided service instructions and
using original Atlas Copco spare parts.
Interval
1.500.000 cycles or 1 year
1.500.000 cycles
3.000.000 cycles
3.000.000 cycles

Calibration recommendations

According to MT Calibration Configuration Manual 9839 0812, the calibration is needed when the
following parts are replaced:
Drive unit
Motor
Front part
Trigger module
EN
© Atlas Copco Industrial Technique AB - 9839 1064 01
Action
Calibrate the tool
Exchange bit grounding
Exchange front part
Exchange motor
Service
13