Mounting the
1 Fit the gasket (2) to the motor housing (3).
gear housing
2 Fasten the gear housing (1) to the motor
housing (3) and fix it with screws (2,5+5
Nm).
3 Fit the gear lever (4) (mount it in
the "hammer" position, the pin must
grasp the elongated hole of the locking
slide).
Mounting the
1 Insert the spring (8) and the retaining
SDS-plus
disk (7).
Reception
2 Depress the retaining disk (7) and insert
the ball (6).
3 Fit the retaining ring (5) and the sliding
sleeve (4).
4 Depress the sliding sleeve and insert the
seal ring (3) into the pass.
5 Fit the spacer (2).
6 Push down the sliding sleeve and fit the
rubber (1).
Test run and
Carry out a test run and check for strange noises.
electrical
Carry out an electrical examination. (See chapter Electrical and Mechanical Test Instruction).
examination
Repair Instruction No. 174.3/95
1 2
3 4
PHE 26 RA
1
2
3
4
5
6
7 8
PAGE
12
14
1 5