- ページ 6

アンプ Bose FreeSpace E4 Series IIのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Bose FreeSpace E4 Series II 16 ページ。 Business music system
Bose FreeSpace E4 Series II にも: オーナーズマニュアル (18 ページ), クイック・スタートアップ・マニュアル (4 ページ), オーナーズマニュアル (15 ページ), オーナーズマニュアル (33 ページ)

Bose FreeSpace E4 Series II オーナーズマニュアル

4.1 Introduction

This section provides instructions for installing the FreeSpace
E4 system hardware on a tabletop or in a rack.

4.2 Included accessories

The following accessories are shipped with the E4 unit in the
FreeSpace E4 System Accessory Kit (PC030105).
• 2-terminal input connectors (6) – For wiring
Auto Volume mics to the
SENSE MICROPHONES jacks
• 3-terminal input connectors (2) – For wiring
equipment to the AUX MIC/LINE 3 jacks
• 4-terminal input connectors (3) – For wiring
equipment to the ZONE 4 LINE OUT,
PAGE/MIC/LINE 4, and
DIRECT IN/CONTROL jacks
• 2-terminal output connectors (5) – For wir-
ing speaker cables to the ZONE OUT jacks
• Rubber feet (4) – For installing the E4 unit on
a level surface
• Replacement voltage label (2) – Used on
the OUTPUT VOLTAGE selection switch
• FreeSpace Installer™ software CD –
Contains application software for pro-
gramming the E4 system

4.0 Hardware Installation

®
25 of 80

4.3 Placement guidelines

• Place the E4 unit where it is protected from heat and allowed
adequate ventilation.
• Place the E4 unit away from direct heat sources, such as heat-
ing vents and radiators.
• Make sure that air can circulate freely behind, beside, and
above the unit. Allow six inches on all sides.
Installer's Note: Do not allow the chassis to exceed the
maximum operating temperature of 50° C (122° F). Be aware
of conditions in an enclosed rack that may increase the tem-
perature above room-ambient conditions.

4.4 Shelf mounting the E4 unit

The E4 unit is ideal for shelf mounting. The included accessory kit
contains four rubber feet for the bottom of the E4 chassis. The
rubber feet will protect the surface on which the E4 unit is
installed and help prevent movement of the E4 unit. Be sure to
follow the "Placement Guidelines" previously described when
choosing a location for the E4 unit.