- ページ 6

水ポンプ DROPSA 3417000 SeriesのPDF マニュアルをオンラインで閲覧またはダウンロードできます。DROPSA 3417000 Series 9 ページ。 Micro-elettric pump

DROPSA 3417000 Series マニュアル
10. INSTRUCTIONS FOR USE
10.1 START UP
Damage to the power supply cable and housing can lead to contact with high voltage parts and present a danger to life:
• Check the integrity of the power supply cable and the unit prior to use.
• Where the cable or the unit is damaged do not operate the equipment!
• Replace the power supply cable with a new one.
• The unit should be opened and repaired ONLY by qualified personnel.
• The pump MUST NOT be submersed in fluids or utilised in environments which are particularly aggressive or
explosive/inflammable if not prepared for this purpose beforehand by the supplier.
• For correct fixing verify the distance between centres.
• Use gloves and safety glasses as required in the lubrication oil safety chart.
• DO NOT use aggressive lubricants with NBR gaskets and seals; if in doubt consult the Engineering Department of
Dropsa SpA, who will provide a chart with the details of recommended oils.
• DO NOT ignore dangers to health and observe all hygiene standards.
10.2 ACTION TO BE TAKEN PRIOR TO START UP
• Verify the integrity of the pump;
• Fill the reservoir with suitable lubricant (min/max indication on the reservoir);
• Ensure the pump is at working temperature and the tubing is free of air pockets;
• Ensure that any electrical connections have been effected correctly (CEI 64/8, IEC 364);
10.3 REGULATION
The only parameter which can be modified is the flow rate; turn adjustment knob clockwise (decrease) or unclockwise
(increase).

FLOW RATE ADJUSTMENT

FOR 1 CC PUMP
FOR 5 CC PUMP
7