- ページ 16

潤滑システム DROPSA VIP4 ToolsのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。DROPSA VIP4 Tools 17 ページ。

Before shipment, the VIP4Tools/Air lubrication panels are carefully packed inside a cardboard box. During transport and
storage of the equipment, pay attention to the direction indicated on the box.
Upon receipt, check that the packaging is not damaged and store the equipment in a dry place.

13. PRECAUTIONS FOR USE

The warnings and risks that using the panel implies must be carefully read. The user must be familiar with
operation through the Operating Manual.
Electrical current
Do not carry out any operations on the machine before disconnecting it from the electrical power supply (on an
electrical level) and ensuring that no one can reconnect it during the operation.
All of the installed, electrical, electronic equipment, reservoirs and base structures must be connected to the
ground line. (see section 6.7).
Flammability
The oil used in the lubrication circuits is a fluid that is not normally flammable. In any case, all possible measures
must be taken to prevent it coming into contact with very hot parts or naked flames.
Pressure
Before any operation, check for the absence of any residual pressure in all branches of the lubricant circuit, that
could cause spurts of oil in the event that fittings or components are disassembled
(see section 6.6).
Noise
The VIP4Tools/Air lubrication panel does not emit excessive noise, remaining below 70 dB (A).
WARNING: before replacing the mini-pumps, remove the lubricant from the reservoir.
Characteristics
Pressure at the hook-up point
Max. quantity of particles in suspension
Max. diameter of the particles
Dew point
Max. quantity of oil in suspension
If natural-based oils compatible with prevailing health regulations are not used, the mixing pressure must be calibrated in
order to prevent the formation and dispersion of spray into the environment.
The approximate mixing pressure is between 1 bar (14.7 psi) and 2.5 bar (36.7 psi).
CHARACTERISTICS OF THE AIR
Operating Type
6 bar min (88.2 psi)
15 mg / Nmc
0.05
2° C (35.6 °F)
5 mg / Nmc
16