BEFORE INSTALLATION
Installation must be carried out in accordance with the current edition of the local wiring regulations
code having jurisdiction. Installation should be performed only by a qualified electrician.
If hand dryer is to be installed with hardwired
stub provided in advance of install by others.
See MT for complete reference to mounting
heights and power KO locations.
66MM[2-19/32"]
[33-55/64"]
[33-5/64"]
INSTALLATION
1. Make sure power supply breaker is switched off. Installation must adhere to the regulations of the
current edition of the local wiring code having jurisdiction. Installation should be performed only by a
qualified electrician.
2. Place Template against wall at desired height (see mounting height recommendations on MT) and mark
locations of eight (8) mounting holes and wire service entry at hard wire entrance.
Note: For two(2) or more dryers units, units should be no closer than 610MM[24"] on centres.
3. Drill the marked hole at Φ8MM / depth 38MM.
3.1 Insert Wall Anchors, Expansion [ D ] inside hole.
3.2 Fix Installation Bracket [ G ] on wall.
4. If the hand dryer is supplied in hard wire type:
860MM
Recommended
840MM
L Min. = 500 MM[19-11/16" ]
220-240V/ 12A
It is recommended to avoid installation
of dryer near high reflective objects
(mirror, stainless steel washbasins, etc.)
in order to avoid faulty function of the
presence sensor.