- ページ 8

エア・ハンドラー Daikin FTKS60FVMVのPDF サービスマニュアルをオンラインで閲覧またはダウンロードできます。Daikin FTKS60FVMV 20 ページ。 Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Daikin FTKS60FVMV にも: サービスマニュアル (20 ページ)

Daikin FTKS60FVMV サービスマニュアル

Vertical Blade ASSYs

5. Vertical Blade ASSYs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1. For auto-swing (right and
left) models
1
Release the right and
left shafts.
2
Unfasten the 3 hooks
for each set of vertical
blade ASSY (9 hooks).
3
Pull the vertical blade
ASSYs to the right and
remove them.
6
All manuals and user guides at all-guides.com
Procedure
Vertical blade ASSY
Interlock rod
Hook
Points
Some models have fan
guards. Remove the fan
guards beforehand.
The unit has 3 sets of
vertical blade ASSYs linked
to one another with interlock
rods.
(R21153)
(R2768)
(R6706)
Removal Procedure