Daikin FTKS60FVMV Руководство по эксплуатации - Страница 8
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Воздухораспределители Daikin FTKS60FVMV. Daikin FTKS60FVMV 20 страниц. Removal procedure, 5.0/6.0/7.1 kw class, 15000/18000 btu/h class
Также для Daikin FTKS60FVMV: Руководство по эксплуатации (20 страниц)
![Daikin FTKS60FVMV Руководство по эксплуатации](/uploads/products/server2/1534804/1534804.jpg)
Vertical Blade ASSYs
5. Vertical Blade ASSYs
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
1. For auto-swing (right and
left) models
1
Release the right and
left shafts.
2
Unfasten the 3 hooks
for each set of vertical
blade ASSY (9 hooks).
3
Pull the vertical blade
ASSYs to the right and
remove them.
6
All manuals and user guides at all-guides.com
Procedure
Vertical blade ASSY
Interlock rod
Hook
Points
Some models have fan
guards. Remove the fan
guards beforehand.
The unit has 3 sets of
vertical blade ASSYs linked
to one another with interlock
rods.
(R21153)
(R2768)
(R6706)
Removal Procedure
Si041254EE