- ページ 6
セキュリティシステム DSC PC51O2-433NAのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。DSC PC51O2-433NA 13 ページ。
The system will generate a General System Supervisory trouble if the module is removed
from the Keybus. If you need to remove the PC5102-433 module from an existing system,
you will have to disable supervision of the PC5102-433.
NOTE
NOTE
NOTE: Deleting all wireless keys from the PC5102-433 or defaulting the PC5102-433 will
NOTE
NOTE
cause a supervisory fault.
To disable PC5102-433 supervision:
1. Disconnect the PC5102-433 from the Keybus
2. Enter [✱][8][Installer 's Code].
3. Enter [902]. The control panel will clear all supervision and re-scan the system for
connected modules. The scan will take approximately one minute.
4. To exit press [#].
To review which modules the control panel is currently supervising:
1. Enter [✱][8][Installer's Code]
2. Enter [903] to display all modules. On LED keypads, light [17] will indicate that the
PC5102-433 is present on the system. On LCD keypads, scroll until the module
name PC5132 appears on the display.
3. To exit press [#].
If the PC5102-433 module does not show on the keypad, one of the following conditions
may be present:
• the module is not connected properly to the Keybus
• there is a problem with the Keybus wiring run
• the module does not have enough power
• no keys have been enrolled on the PC5102
NOTE: The PC5102-433 will be supervised and displayed as a PC5132.
4.3
PC5102-433 Software Default
Returning the PC5102-433 programming to factory default settings is a quick way to
remove all the enrolled wireless keys from the system and reset all the programming in
section [804].
NOTE
NOTE: Performing this procedure will not change any programming sections except
NOTE
NOTE
NOTE
[804]. Resetting the control panel to factory default settings will not return the PC5102-
433 module to factory default settings.
To restore the PC5102-433 programming to the factory default settings:
1. Enter [✱][8] [Installer's Code].
2. Enter programming section [996].
3. Enter the Installer's Code, followed by [996] again. The programming for the
PC5102-433 will be restored to its factory default settings.
4. To continue programming the unit, exit installer's programming by pressing [#] and
then re-enter installer's programming by entering [✱][8] [Installer's Code].
For instructions on restoring the default programming of the control panel or any other
connected module, see your system Installation Manual.
4.4
Deleting Wireless Keys
To remove a wireless key from the system, follow the guideline for enrolling a wireless key
(see section 3.2). Program the ESN as [000000]. The wireless key will then be removed
from the system.
Now that you have completed all PC5102-433 related programming, you can test and
mount the receiver. See Section 5 for more information.
Section 5: Testing & Mounting
Section 5: Testing & Mounting
Section 5: Testing & Mounting
Section 5: Testing & Mounting
Section 5: Testing & Mounting
5.1
Test the Reception of Wireless Keys
It is very important to test each wireless key. Following these steps will test the signal strength
between the PC5102-433 and the wireless key.
firealarmresources.com
6