セキュリティセンサー DSC LC-101CAM SeriesのPDF インストレーション・インストラクションをオンラインで閲覧またはダウンロードできます。DSC LC-101CAM Series 2 ページ。 Quad element pir mono/colour camera motion detector with pet immunity

DSC LC-101CAM Series インストレーション・インストラクション
LC-101CAM
Quad Element PIR Mono/Colour Camera
Motion Detector with Pet Immunity
A n ew g en erat ion o f p rofessio nal mo vem en t sp read analyzing PIR detectors w ith Mo no / Co lo ur Camera
Video sensing device * High sensitivity and high resolution board camera. * Electronic shutter control.
Audio sensing device * Omnidirectional response.* High sensitivity.
TYPICAL INSTALLATION
Select mounting location
Choose a location most likely to intercept an intruder. (Our recommendation is a corner installation). See detection pattern (Fig.3). The quad-
element high quality sensor detects motion crossing the beam; it is slightly less sensitive detecting motion toward the detector. The LC-101CAM
performs best when provided with a constant and stable environment.
Avoid the Following Locations * Facing direct sunlight. * Facing areas that may change temperature rapidly. * Areas where there are air ducts
o r s ubs ta ntia l ai r flo ws. T h e LC- 10 1CA M per fo rm s b etter wh en pr ov i ded w ith a co ns tant a nd s tabl e en vi r onm ent.
MOUNTING DETECTOR BASE
1. To remove the front cover, unscrew the holding screw and gently raise the front cover. Fig.2-12 2. To remove the PC board, carefully unscrew
the holding screw located on the PC board. Fig.2-7 3. Put wire through the bracket and holes "A". Fig.1 4. Mount the detector base to the wall
or on the ceiling with a suitable bracket. (Install bracket). 5. Reinstall the PC board by fully tightening the holding screw. Connect wire to terminal
block. Fig.5 6. Connect the camera cable to connector in PC 7. Replace the cover by inserting it back in the appropriate closing pins and screw
in the holding screw.
DETECTOR INSTALLATION
Terminal Block Connections (See Fig.5)
Terminals 1 & 2 - Marked "T1,T2" (TAMPER) If a Tamper function is required connect these terminals to a 24-hour normally closed protective
zone in the control unit. If the front cover of the detector is opened, an immediate alarm signal will be sent to the control unit.
Terminals 3 & 4 - Marked "AUDIO: OUT, GND" This is the audio signal output. These two terminals should be connected to an audio input.
Terminals 4 & 5 - Marked "VIDEO: GND, OUT" This is the video signal output. These two terminals should be connected to video input.
Term inals 6,7 & 8 - Marked "RELAY: NO, COM & NC" These are the output relay contacts of the detector. Connect to a normally closed or
normally opened zone in the control panel.
Terminal 9 - Marked "-" (GND) Connect to the negative Voltage output or ground of the control panel.
Term inal 10 - Marked "+ "( +12V) Connect to a positive Voltage output of 8.2 -16Vdc source (usually from the alarm control unit)
FIG 1 - Knockout h oles
A
A
B
Series Mono/Colour
Installation Instructions
1
3
7
5
11
7
10
FIG 2 - Detector Installa tion
4
6
8
9
12
15m
FIG 3 - Lens pattern
AUDIO
VIDE O
RELAY
T2
T1
OUT
GND
OUT
N.O
1
2
3
4
5
6
FIG 4 - Terminal block
C
NC
- 12V +
7
8
9
10