- ページ 5
コントロールユニット DSC PC5928のPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。DSC PC5928 16 ページ。 Audio interface module
DSC PC5928 にも: ユーザー・インストラクション (2 ページ)
G
E
T
T
2.4
Telephone Line Connection
The PC5928 has 4 terminals for the telephone line connection (TIP, RING, T1 and R1). The
wiring must be as follows:
• Incoming line - PC5010 TIP and RING
• PC5010 T1 and R1 - PC5928 TIP and RING
• PC5928 T1 and R1 - house phone
If there is an Escort5580 connected as well, it must be connected between the
PC5010 and PC5928 (phone line).
2.5
Enabling PC5928 Supervision
The PC5928 will function properly as soon as all wiring is complete and power is applied.
However, in order to fully supervise the PC5928 from the PC5010 panel, the following steps
must be taken.
Step 1 - At a keypad enter [ ] [8] [Installer Code] to enter Installer Programming.
Step 2 - Press [902] to enable supervision. The panel will automatically search for all
modules on the system. Press [#] to exit Installer Programming. The search takes
approximately 1 minute. From this point on, if any modules are removed from the
system, a Supervisory trouble will be generated.
Step 3 - To confirm the supervision, re-enter Installer Programming and then enter [903]. On
LED keypads, Light 21 ON represents successful PC5928 supervision. On LCD
keypads, the description PC5928 will be displayed if successful.
Step 4 - If this is not successful, check all wiring to the PC5928.
I
N
G
S
5
firealarmresources.com
T
A
R
T
E
D