- ページ 4

ネットワーク・ルーター 3onedata ICS5028G SeriesのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。3onedata ICS5028G Series 5 ページ。 Layer 3 industrial

3onedata ICS5028G Series ユーザーマニュアル
ON/OFF
System is not running well
RUN
Blinking
System is running well
When the alarm is enabled,
ON
power or the port's link is
inactive.
Alarm
Power and the port's link is
OFF
active, the alarm is disabled.
ON
Port connection is active
Link/ACT
Blinking
Data transmitted
(1~28)
OFF
Port connection is not active

【Installation】

Before installation, confirm that the work environment meet the
installation require, including the power needs and abundant
space. Whether it is close to the connection equipment and other
equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or
the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m)
according to reasonable scheme.
4. Power: 100-240VAC power input
5. Environment: working temperature: -40~75℃
Storage Temperature: -40~85℃
Relative humidity 5%~95%
Rack mount installation
In most of industrial application, it is convenience to use rack
mount installation, the step of installation is as follows:
1. Check if have rack mount installation tools and components
(The package provided parts of components)
2. Check installation place strong or not, have the place to install
the device or not.
3. Put the device into rack, aim at the screw hole of device and
rack, fixed it in strong screw. Easy and convenience to
operation.
Wiring Requirements
Cable laying need to meet the following requirements,
1. It is needed to check whether the type, quantity and
specification of cable match the requirement before cable
laying;
2. It is needed to check the cable is damaged or not, factory
records and quality assurance booklet before cable laying;
3. The required cable specification, quantity, direction and
laying position need to match construction requirements, and
cable length depends on actual position;
4. All the cable cannot have break-down and terminal in the
middle;
5. Cables should be straight in the hallways and turning;
6. Cable should be straight in the groove, and cannot beyond the
groove in case of holding back the inlet and outlet holes.
Cables should be banded and fixed when they are out of the
groove;
7. User cable should be separated from the power lines. Cables,
power lines and grounding lines cannot be overlapped and
mixed when they are in the same groove road. When cable is
too long, it cannot hold down other cable, but structure in the
middle of alignment rack;
8. Pigtail cannot be tied and swerved as less as possible.
Swerving radius cannot be too small (small swerving causes
terrible loss of link). Its banding should be moderate, not too
tight, and should be separated from other cables;
9. It should have corresponding simple signal at both sides of the
cable for maintaining.

【Specification】

Technology
Standard: IEEE802.3, IEEE802.3u, IEEE802.3z/ab, IEEE802.3x,
IEEE802.3ae, IEEE802.1d, IEEE802.1w, IEEE802.1s,
IEEE802.1q, IEEE802.1p, IEEE802.1x, IEEE802.3ad
- 4 -
Flow control: IEEE802.3x flow control, Back Pressure flow
control
Protocol
IGMP Snooping , GMRP, SNMPv1/v2/v3, QOS,
STP/RSTP/MSTP, DHCP Server/Client, DHCP, VLAN, LLDP,
SNTP, Telnet, HTTP/HTTPS, SSH, LACP
Layer 3 Switching Technology
Static routing, RIP V1/V2, OSPF, VRRP, BGP
Interface
RJ45 port: 10/100 /1000BaseT(X), flow control, full / half duplex,
adaptive work mode, MDI/MDI-X adaptive
Combo port: 1000Base-X SFP slot or 10/100/1000Base-T(X)
Gigabit SFP port: 1000Base-X SFP slot
10GbE SFP port: 10GbE SFP+ slot
Console port: CONSOLE Admin Port (RJ45)
Alarm port: 5-core 5.08mm wiring terminal (R+/R-),
2-way relay alarm output
Transmission distance
Twisted-pair: 100m (standard CAT5/CAT5e cable)
Multi-mode fiber: 1310nm, 2km
Single mode fiber: 1310nm, 20/40Km
1550nm, 60/80/100/120Km
LED indicator
Power indicator: P1/P2
Alarm indicator: ALM
Operation indicator: RUN
Port connection / operation status indicator: Link/ACT (1~28)
Switch attribute:
Transmission mode: store-and-forward
MAC address: 16K
Cache: 12Mb
Switched Bandwidth: 128G
1000M forwarding rate: 1488100pps
10000M forwarding rate: 14881000pps