- ページ 16

セキュリティシステム Duevi PEPEROSSOのPDF 設置および使用マニュアルをオンラインで閲覧またはダウンロードできます。Duevi PEPEROSSO 19 ページ。 Dissuader with nebulization irritating gas

Battery substitution

Verify periodically the battery status and substitute if necessary with a new one.
FOLLOW STRICTLY AND IN PRECISE ORDER THE FOLLOWING INSTALLATION
INSTRUCTIONS, OTHERWISE MAY RESULT AN ACCIDENTAL NEBULISATION OF
HARMFUL GAS
1.
Deactivate the control panel with tamper control excluded
2.
Ensure Peperosso is blocked with IN1 and IN2 at +12 V
3.
Open the cover
4.
Cut the straps and remove the spray cans, unplug the CN2 motor connector
5.
Unplug the CN1 connector
6.
Remove the motor base unscrewing the three screws, unplug the CN7 end-line connector and
the BAT battery connector
7.
Unscrew the battery bracket and remove it
8.
Place the new battery and fix it with the bracket
9.
Plug in the motor and end-line connectors
10.
Plug in the battery connector: the motor moves the plunger forward
11.
Screw the three screws the motor base
12.
Plug in the CN1 connector already cabled
13.
Enable Peperosso removing the positive +12 V
14.
Press K1 button to bring the plunger to rest
15.
At this point make a functioning test using the test spray can (containing water, see "Test"
paragraph)
16.
At the end of test block Peperosso using IN1 (provide a positive 12 V)
17.
Peperosso must stay at rest with the plunger completely back and settled
Only in this position is possible to fix the spray cans with the straps (fig. 6)
In this phase, to avoid unwanted nebulisations, (caused by error on wiring or moved on CN1),
remove the CN2 motor connector, in this way the plunger is mechanically blocked allowing a
secure installation
18.
Close the cover
19.
Plug in the CN2 motor connector
20.
Peperosso is ready to be used
from IN1 from control panel
16