DECLARATION OF CONFORMITY
The product specified below complies with the essential requirements of the following
Directives and carries the CE mark accordingly:
2011/65/EU (RoHS)
2004/108/EC (EMC)
Standards to which Conformity is Declared:
DIRECTIVE 2014/30/EU (Electromagnetic Compatibility EMC)
Regulation (EU) 2016/426, EN 521:2006(Burning Gaseous Fuels)
Directive 2006/42/EC (New Machinery Directive)
DIRECTIVE 2001/95/E (General Product Safety Directive)
Rapex (Risk Analysis)
Type of Equipment
Model No.
Year of Manufacture
CaseLife Annealing Machine
CL1 V1.0 / CL1 V1.1
2019
Gearbox setup
To adjust the wheel gap for different calibres, first loosen the two gearbox retaining wing bolts on the rear gearbox
housing. This will allow the housing, shafts and load wheels to move freely.
With a brass case in the top load wheel groove, move the top load wheel groove to the right loading slope. Adjust
the gap to allow the case to pass the slope and tighten the rear bolts. (Too much or little gap will cause snagging)
Case length
Extra case length support can be gained by loosening the load wheel grub screws and sliding the wheels along the
shaft. Retighten the grub screws to set. (Don't forget to check the 4 and 12 o clock position as in section wheel
alignment)
The lower wheel side case paddle is adjustable for case width and reversible to support longer cases.