- ページ 8

DCドライブ Danfoss Holip HLP-V SeriesのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Danfoss Holip HLP-V Series 10 ページ。

Danfoss Holip HLP-V Series 取扱説明書
Contorl card, analog inputs:
No. of programmable analog voltage inputs/thermistor inputs
Terminal no.
Voltage level
Input resistance, Ri 10
No. of programmable analog current inputs
Terminal no.
Current range
Input resistance, Ri
Resolution
Accuracy on input
Scanning time per input
Terminal no. ground 5
Reliable galvanic isolation: All analog inputs are galvanically isolated from the supply voltage (PELV)* as well
as other inputs and outputs.
Control card, pulse/encoder input:
No. of programmable pulse/encoder inputs
Terminal no.
Max. frequency on terminal 17
Max. frequency on terminals 29, 32, 33
Max. frequency on terminals 29, 32, 33
Voltage level
Voltage level, logical '0'
Voltage level, logical '1'
Maximum voltage on input
Input resistance, Ri
Scanning time per input
Resolution
Accuracy (100-1 kHz), terminals 17, 29, 33
Accuracy (1-5 kHz), terminal 17
Accuracy (1-65 kHz), terminals 29, 33
Reliable galvanic isolation: All pulse/encoder inputs are galvanically isolated from the supply voltage (PELV)
*. In addition, pulse and encoder inputs can be isolated from the other terminals on the control card by con-
necting an external 24 V DC supply and opening switch 4.
Control card, digital/pulse and analog outputs:
No. of programmable digital and analog outputs
Terminal no.
Voltage level at digital/pulse output
Minimum load to ground (terminal 39) at digital/pulse output
Frequency ranges (digital output used as pulse output)
Current range at analog output
HLP-V Series
53, 54
0 - ±10 V DC (scalable)
0/4 - ±20 mA (scalable)
200
10 bit + sign
Max. error 1% of full scale
3 msec.
17, 29, 32, 33
5 kHz
20 kHz (PNP open collector)
65 kHz (Push-Pull)
0-24 V DC (PNP positive logics)
< 5 V DC
>10 V DC
28 V DC
3 msec.
10 bit + sign
Max. error: 0.5% of full scale
Max. error: 0.1% of full scale
Max. error: 0.1% of full scale
42, 45
0 - 24 V DC
600
0-32 kHz
0/4 - 20 mA
2
k
1
60
5
4
2 k
2
7