Installation
Instructions
Please Note:
This product should only be installed by a
qualifi ed electrician or competent heating
installer and should be in accordance with the
current edition of the IEEE wiring regulations.
Specifi cation
Thermostat Features
Power supply
Memory backup
Switching action of output relay
Switch rating of relay contact,
voltage and current
Transmitter frequency (RF only)
Transmitter range (RF only)
Rated Impulse Voltage
Dimensions (mm)
Ball Pressure Test
Temperature Range
Design Standard
Control Pollution Situation
Time accuracy
Temperature accuracy
*1: Unit must powered up for 6 days to charge cell before full back-up is available
Important note RF products: Ensure that there are no large metal objects, such
as boiler cases or other large appliances, in line of sight between the transmitter
and receiver as these will prevent communication between thermostat and receiver.
TP7000-RF
TP7000
2 x AA/MN1500/LR6 alkaline
batteries
Capacitor during battery change
for 1 minute
N/A
N/A
433.92 MHz
30 meters max.
N/A
138 wide x 88 high x 28 deep
75°C
5-30°C
EN 60730-2-7 (EN300220 for RF)
Degree 2
± 1 min.
±1°C
GB
TP7000M
230v, 50 Hz
Rechargable
cell, 24 hrs (*1)
1 x SPDT, Type 1B
3(1) A, 230 volts
N/A
N/A
2.5Kv
3