Measuring Phase of Effects Unit Connected to ARC-4

Optional Cable RC-7
Turn on the power to the PHA-1, ARC-4, and your effects unit(s).
Turn the TEST SIGNAL LEVEL knob fully counterclockwise so that
the test signal will not be output.
1. Press the SOURCE SELECT switch until "OPTION-2" is shown in
the top line of the Display.
2. Press the TEST switch to select the measurement mode to be
used. Measurement modes switch each time when the TEST
switch is held pressed for about 1 second.
Two Types of Phase Measurements and Phase Judgement Principle ➔ p.5
3. Recall the desired ARC-4's preset.
By putting the ARC-4 in Direct mode and turning on the
loops one by one, it is possible to check the phase of each
effects unit.
4. Slowly turn the TEST SIGNAL LEVEL knob clockwise. The
waveform and level of the signal fed into the PHA-1.
8
Adjust the TEST SIGNAL LEVEL knob so that 4 to 9 LEDs of the
level meter illuminate.
Adjusting Signal to be Measured ➔ p.6
5. To set the device in the reversed phase from the phase
judgement result, turn on the ARC-4's Phase Invert function
and save the setting in a preset.
NOTE
If the recalled combination of effects units contains a delay or reverb
unit, set the effect sound to minimum and perform the measurement.

Notes on Level Meter Display

Placing the level shown at the upper right corner of the Display
as the reference (0 dB), each LED element of the level meter
illuminates when the signal level reaches the corresponding level.
For example, if "-10dBm" is shown at the upper right corner
of the Discplay, the 7th LED (reference)
10 (Top)
+3dB
9
+2dB
illuminates when the signal level exceeds
8
+1dB
7
0dB
-10 dBm. Similarly for "-22dBm," the
6
-1dB
5
-3dB
7th LED illuminates when the signal level
4
-5dB
3
-7dB
exceeds -22 dBm.
2
-10dB
1 (Bottom) -20dB

Precautions for Battery Use

The PHA-1 can be driven by a 9-volt battery. When the Display
shows "Low-Battery," replace the battery with a new one. If
the PHA-1 is not used for a long period of time, remove the
battery and store them separately.