- ページ 5

インターホン・システム dupol up200-gsmのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。dupol up200-gsm 7 ページ。 Intercom and access control unit operating on mobile gsm network

SETTING WITH SMS COMMANDS
Configuration of the unit is possible by sending the appropriate commands in SMS to the module's phone number. It
is possible to send more commands (settings) in the same SMS, but the length of the message must not exceed 140
characters! Each message must begin with the password using the PWD=password# command and each command
must end with # character, else the module does not apply the modifications. The following table contains the
configuring and query commands:
PWD=1234#
PWC=new password #
RESET#
UPTEL1=phone number#
UPTEL2=phone number#
UPAUTO=ON# vagy OFF#
LOWTEL1=phone number#
LOWTEL2=phone number#
LOWAUTO=ON# or OFF#
OUT=activation event#
RELAY=activation event#
RINGTIME=duration#
CALLTIME=duration#
RTIME=duration*NO# or NC
OUTTIME=duration*NO# or NC
RTEL=phone number*REL*OUT#
RTELDEL=phone number#
STATUS?#
RTEL?#
INFOSMS=phone number#
This scenario shows the configurations for the following requirements: phone number 2 only for upper pushbutton,
auto switch to the secondary phone, VOUT control (for electric lock) by phone and input contact, duration is 10sec,
both phone numbers are able to control the gate control's relay by a free call, relay activation time is 5sec.
Other call parameters: Ringingtime=25sec; maximum duration of the conversation=120sec; forwarding prepaid card
information to primary phone number
SMS message:
PWD=1234#UPTEL1=0036309999999#UPTEL1=0036201111111#UPAUTO=ON#OUT=IN+PHONE#
OUTTIME=10*NO#RTEL=0036309999999*REL#RTEL=0036201111111*REL#RTIME=5*NO#
RINGTIME=25#CALLTIME=120#INFOSMS=0036201111111#
Configuration commands
Password for programming, default setting:1234
Changing the password. The password is a 4-digit number.
Resetting the settings and the password to default.
Primary phone number for upper pushbutton.
Secondary phone number for upper pushbutton.
In case the call to UPTEL1 fails, UPTEL2 phone number will be called
without having to push the button again, if the parameter is ON.
Primary phone number for lower pushbutton.
Secondary phone number for lower pushbutton.
In case the call to LOWTEL1 fails, LOWTEL2 phone number will be called
without having to push the button again, if the parameter is ON.
Voltage output control: OFF: disable, BUTTON: when button is pressed
INPUT: when input is activated, PHONE: during call, pressing any of the
phone's keys, IN+PHONE: INPUT and PHONE enabled
Relay control: OFF: disable, BUTTON: when button is pressed
INPUT: when input is activated
Ringing time of the telephone to restrict the reach of voice mail. (10-120sec)
Maximum duration of the conversation. (10-600 sec)
Duration and idle mode of the relay output activation. (1-120 sec)
Duration and idle mode of the voltage output activation. (1-120 sec)
Setting the phone numbers for relay or voltage output activation. For output
activation the suffix after the phone number is necessary.
*REL: switch the realy, *OUT: switch the voltage out,
*REL*OUT switch both. Up to 100 users.
Delete the selected phone number.
Query of the settings except RTEL list.
Query of the RTEL list.
Forwards the incoming SMS messages.
UP200-GSM Rev.1.2 08/01/2014