- ページ 3

ストレージ Addonics Technologies RT3DAHEU3のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Addonics Technologies RT3DAHEU3 4 ページ。

Default factory DIP Switch setting:
SW1 – RAID Setting DIP Switch
BZS – Error buzzer function
EZ –
Automatic rebuilding to spare drive (one of the drives on the raid is set as a
spare). If EZ is ENABLED anda drive failure occurs, the spare will
automatically act as a drive replacement and rebuilding will automatically
start.
M2 –
RAID mode 2
M1 –
RAID mode 1
SW1
M0 –
RAID mode 0
1.
Error buzzer function is ENABLED (BZS) when dip switch is in OFF position
2.
Auto-rebuilding to spare drive is DISABLED (EZ)
3.
Individual drive mode is ENABLED (M0~M2)
Note: When the default factory RAID setting is used, independent drive configuration
and optical drive are supported only when connecting to controllers with Silicon
Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM)
compatible. Simultaneous DVD writing was tested using the Nero Burning Rom.
LED Pin Header
J3
P5 P0 P1 P2 P3 P4
Error LED
J1 – Drive Activity LED
P5 –
Activity LED for eSATA host port lights up when it is connected to a
SATA controller card.
P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is
connected and blinks when there's drive activity.
J3 – Error LED
P5 –
error LED for eSATA host port
P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5
3
www.addonics.com
1
2
3
4
5
BZS EZ M2 M1 M0
J1
P5 P0 P1 P2 P3 P4
Activity LED
Technical Support (M-F 8:30am - 6:00pm PST)
Setting or Modifying the RAID Mode Using the JMicron
HW RAID Manager Utility Program:
1.
For Windows users, install the JMicron HW RAID Manager located on the
SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This
manager can be use to create and monitor the status of the RAID volume.
It is recommended to use the default factory RAID DIP switch setting when
using the JMicron HW RAID Manager.
2.
Modify the RAID mode on the 5-port HPM-XA using DIP switch
Recommended to be used on operating system without JMicron HW RAID
Manager support like Linux, Mac & Solaris. Windows users can also use the
procedure below.
Note: Steps A to D need to be performed each time the raid mode is modified.
a.
Set the DIP switch to factory default setting.
SW1
1
2
BZS EZ M2 M1 M0
b.
Press the RAID setting button with a ball point pen.
c.
While pressing the RAID setting button turn on the system power
where the HPM is connected. The buzzer will sound while holding the
RAID setting button. Release it after at least 5 seconds for hardware
initialization. A single beep will be heard to indicate initialization is
completed. The above steps act as a reset.
d.
Power off the system power.
Phone: 408-453-6212
3
4
5
Email: www.addonics.com/support/query/
4