- ページ 2

ヒーター Consort CSL2LSTのPDF インストレーション&オペレーションマニュアルをオンラインで閲覧またはダウンロードできます。Consort CSL2LST 4 ページ。 Sl wireless controlled low surface temperature panel convector heaters
Consort CSL2LST にも: インストレーション&コントロール・マニュアル (4 ページ)

Consort CSL2LST インストレーション&オペレーションマニュアル
2
General Safety
Our Low Surface Temperature heaters
have been designed and built to the
NHS requirement for safe surface
temperatures which is that no surface
which can be touched by the user will
be more than 43 ºC (at a room
temperature of 21 ºC) This means that
our Low Surface Temperature heaters
out-perform the European Standard by
a significant margin.
The appliance is not intended for use by
persons (including children) with
reduced physical, sensory or mental
capabilities or lack of experience and
knowledge unless they have been given
supervision or instruction concerning use
of the appliance by a person
responsible for their safety. Children
should be supervised to ensure that they
do not play with the appliance.
Safety Monitor
As part of the intelligent control (see
section 15), the heater has built-in safety
monitoring. In the unlikely event of a
fault, the safety monitoring will help
prevent high surface temperatures. The
safety monitor will identify overheating,
fan failure and certain electronic faults.
When the safety monitor identifies a
fault, the heater runs in restricted mode.
However, in the event of a serious fault
the heater stops running. The heater
indicates a fault by beeping twice. It will
not beep again until the unit is switched
off and then back on, but the LED will
flash red continuously.
Thermally Operated Cut-Out
The appliance is fitted with a thermally
operated cut-out (TOC). In the unlikely
event that the safety monitor fails, this
safety device will switch the heater off if
the appliance overheats. If the TOC has
tripped there is a high possibility the
heater is faulty and should be checked
by a qualified person. The TOC can only
re-set after the appliance has cooled
down, however we advise not to do this
until the heater has been checked
In order to re-set the TOC, proceed as
follows:
62001231 Iss 03
Switch off appliance and leave for
·
approximately 10 minutes.
Switch appliance back on and the
·
TOC will re-set.
Ensure that the appliance is
·
functioning correctly. If the TOC
control operates again, the
appliance should be checked by a
qualified person.
The heater carries a 'Do Not Cover' label to
warn the user that if the appliance is
covered, there is a risk of overheating.
Warning
Do NOT site the appliance in a corner.
·
Do NOT handle the appliance with wet
·
hands.
Do NOT use the appliance in workshops or
·
rooms where excessive dust is generated
or present.
Ensure that nothing is pushed into the air
·
outlet of this appliance.
Do NOT touch outlet grille when the
·
appliance is in use.
Do NOT cover or restrict the appliance
·
when in use.
Do NOT use the appliance if damaged.
·
Do NOT leave the appliance unattended
·
where young children are present.
This appliance must be earthed.
·
Intelligent Fan Control
The intelligent fan control incorporates one of
the latest low energy consumption EC
motors. This allows the heater to operate
quietly, whilst still providing the best possible
levels of comfort.
The intelligent fan control is only activated
when the heat is switched on. If the heater is
running in fan/boost mode only (heat
switched off), then the fan will operate at a
fixed speed.
When activated, the intelligent fan control
detects the temperature of the room.
Depending on which heat mode is
activated, it will calculate the best possible
airflow temperature and will adjust the fan
speed accordingly.
NOTE: When turning the heater on, or changing
heat mode or fan speed mode, the fan will
respond accordingly after a small time delay.