リフティングシステム APlusLift HW-8SのPDF インストレーション&オペレーションマニュアルをオンラインで閲覧またはダウンロードできます。APlusLift HW-8S 19 ページ。 4-post portable storage car lift
Step 3 (Installing Cables)
• The cables come pre-installed in the runway along with the cylinder. Route the cables
in a manner in such that the two rear cables are in the front of the terminal block and
the front two corners are in the back of the terminal.
• Install the cables by running the ram manually by pulling it out on the ram by hand. Do
not add hydraulic fluid yet as the ram will not be able to be operated manually once
hydraulic fluid is added.
• Run cables through the pulleys on the cross rail and up towards the top of the columns
where there is a termination point.
• Attach the front lock release.
• Connect the release T rod with the long rod under runway.