- ページ 8

ミシン DURKOPP ADLER DAC classic 867のPDF 補足説明をオンラインで閲覧またはダウンロードできます。DURKOPP ADLER DAC classic 867 20 ページ。 Flatbed machines throat plate slide interrogator
DURKOPP ADLER DAC classic 867 にも: 取扱説明書 (19 ページ)

DURKOPP ADLER DAC classic 867 補足説明
2. Tighten the proximity switch (2) to the metal bracket (4) using the nuts
3. Screw the metal bracket (4) into the threaded hole in the hook bearing
 This setting requires a safe switching distance of approx. 0.5 mm
Information
Switching distance between throat plate slide (6) and proximity switch (2):
• Standard switching distance: 0.8 mm
• safe switching distance: 0.64 mm
Laying the cable
Fig. 5: Assembling the throat plate slide interrogator (3)
(2)
(7) - Cable
4. Swivel up the machine head ( Operating Instructions).
5. Tighten the cable (7) of the proximity switch at the hook support.
6. Lay the cable (7) to the right towards the circuit board along the oil
6
and toothed washers:
• The distance between the lower edge of the metal bracket (4) and
the upper edge of the proximity switch (2) is 17 mm
• Machine with short thread cutter (KFA): Tighten the proximity
switch (2) at position (3) (right hole in the metal bracket (4)).
• Machine with/without thread cutter (FA): Tighten the proximity
switch (2) at position (1) (left hole in the metal bracket (4)).
using the screw (5).
between throat plate slide (6) and proximity switch (2).
- Proximity switch
line (8).
Assembling the throat plate slide interrogator
(8) - Oil line
Additional Instructions 867 M-TYPE - 00.0 - 05/2018