2. Tighten the proximity switch (2) to the metal bracket (4) using the nuts
3. Screw the metal bracket (4) into the threaded hole in the hook bearing
 This setting requires a safe switching distance of approx. 0.5 mm
Information
Switching distance between throat plate slide (6) and proximity switch (2):
• Standard switching distance: 0.8 mm
• safe switching distance: 0.64 mm
Laying the cable
Fig. 5: Assembling the throat plate slide interrogator (3)
(2)
(7) - Cable
4. Swivel up the machine head ( Operating Instructions).
5. Tighten the cable (7) of the proximity switch at the hook support.
6. Lay the cable (7) to the right towards the circuit board along the oil
6
and toothed washers:
• The distance between the lower edge of the metal bracket (4) and
the upper edge of the proximity switch (2) is 17 mm
• Machine with short thread cutter (KFA): Tighten the proximity
switch (2) at position (3) (right hole in the metal bracket (4)).
• Machine with/without thread cutter (FA): Tighten the proximity
switch (2) at position (1) (left hole in the metal bracket (4)).
using the screw (5).
between throat plate slide (6) and proximity switch (2).
- Proximity switch
line (8).
Assembling the throat plate slide interrogator
(8) - Oil line
Additional Instructions 867 M-TYPE - 00.0 - 05/2018