Never use a fuse with a higher amperage than specified.
Important
If a fuse continues to blow, the fault in the wiring, boards (if present) or motors must be Identified and repaired.
Have the machine checked by qualified personnel.
8.2.5. Fuses: replacing
1. Turn the key switch to the "0" position.
2. Rotate the cowling to access the machine compartment
3. Remove the fuse holder cover
4. Check the fuses.
5. Replace with a new fuse.
6. Close the cover again
Fuse table: For the complete fuse table, see the spare parts catalogue.
8.2.6. Side brush belt: replacing
1. Rotate the top cowling.
2. Remove the pulley (ref. 2) belt (ref. 1)
3. Unscrew the fixing pin (ref. 3) and side arm hooks (ref. 4) from the idle toothed ring.
4. Remove the belt (ref. 1) from the side arm (ref. 4)
5. Replace the belt
6. Attach the side arm (ref. 4) to the idle toothed wheel again.
7. Screw up the pin (ref. 3).
8. Fit the belt (ref. 1) onto the pulley (ref. 2)