TYPE 5320

3.4 Dimensions

4. Installation instructions

4.1 Pre-installation

Verify that the nameplate of the limit switch box match the specifications needed – correct model
number, voltage and enclosure type - before installation and use.
 Wiring connections should be in accordance with the diagram attached to the inside of the
top casing cover.
 The two conduit cable entries shall be sealed in a proper manner until cable works is
finalized.
 Position indicator and switch box covers are sealed by use of o-rings. Please take care of o-
ring in order not to cause any damage to the o-rings during disassembly or reassembly.
 The position of the limit switches / cams have not been adjusted at the factory. Therefore a
final adjustment of those is needed before use.
 Do not use in areas where explosion proof equipment is required. These types of limit
switches are designed as weatherproof types – not explosion proof types.

4.2 Limit switch box mounting

INSTALLATION, OPERATION AND MAINTENANCE MANUAL
I O M . U K . D V C . 5 3 2 0 . 3 0 0 6 1 5 - R E V . B
PAGE 6