- ページ 13
送信機 Datcon DT1600 U SeriesのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Datcon DT1600 U Series 20 ページ。 Ac voltage transmitters
DT1600 Ux xx xx
Wiring plan, connecting
the signal processing
unit and the power
supply
(see also "Application
example")
Be careful the polarity of
the cables
Checking the
connections
Put the instrument
under supply voltage
20180621-V0
5.3. Connecting the signal processing unit and the
power supply
The following figure shows the wiring plan, connecting the
signal processing unit and the power supply:
1. Loosen terminal screws.
2. Insert the wire ends into the open terminals according to
the wiring plan.
3. Screw the terminal in.
4. Check the hold of the wires in terminals by pulling on
them firmly.
Check if the cables are connected properly (have you
connected all the cables, have you connected to the right
place, do not the cable-ends touch each other).
5.4. Put the instrument under supply voltage
After you have completed the connections, put the
instrument under supply voltage. If the connection is correct
the green indicator give light and you can measure output
current or voltage on the output of the instrument according
to the measured value of the transmitter.
13