IMPORTANT SAFETY INSTRUCTIONS (CONT.)
4) Test the door's safety features at least once a month. After adjusting either the force or the
limit of travel, retest the door operator's safety features. Failure to adjust the operator
properly may cause severe injury or death.
5) KEEP DOORS PROPERLY OPERATING AND BALANCED. See Door Manufacturer's Owner's
Manual. An improperly operating or balanced door could cause severe injury or death. Have
trained door systems technician make repairs to cables, spring assemblies and other hardware.
6) SAVE THESE INSTRUCTIONS.
1) DISCONNECT POWER AT THE FUSE/BREAKER BOX/DISCONNECT BEFORE PROCEEDING
WITH ANY WIRING OF THIS UNIT.
2) THE UNIT MUST BE PROPERLY GROUNDED. A GROUND SCREW IS SUPPLIED IN THE
ELECTRICAL BOX FOR CONNECTION OF THE POWER SUPPLY GROUND WIRE. FAILURE
TO PROPERLY GROUND THIS UNIT COULD RESULT IN ELECTRICAL SHOCK AND
SERIOUS INJURY.
3) FIELD WIRING OF OPERATOR MUST BE PERFORMED BY QUALIFIED PERSONNEL.
4) OPERATOR MUST BE WIRED PER WIRING DIAGRAMS PROVIDED IN THIS OWNERS
MANUAL ONLY.
5) OPERATOR MUST BE WIRED IN ACCORDANCE WITH LOCAL ELECTRICAL CODES.
NOTE: THE OPERATOR SHOULD BE ON A SEPARATE FUSED LINE OF ADEQUATE
CAPACITY.
6) USE 18 GA STRANDED COPPER WIRE MINIMUM FOR ALL CONTROL CIRCUIT
CONNECTIONS.
7) DO NOT INSTALL ANY WIRING OR ATTEMPT TO RUN THE OPERATOR WITHOUT
CONSULTING THE WIRING DIAGRAM.
8) SET OPERATOR LIMIT SWITCHES BEFORE CONNECTING ANY ENTRAPEMENT
PROTECTION DEVICES TO THE OPERATOR.
Before your operator is installed, be sure the door has been properly aligned and is working
smoothly. Refer to the Door Installation Instructions for proper operator installation. This
motor operator is an integral part of the door system. The motor operator and governor (if
provided) controls door descent speed under power outage conditions.