- ページ 4

バッテリーチャージャー Gacell CT-1000のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Gacell CT-1000 9 ページ。

Gacell CT-1000 ユーザーマニュアル
to solid, the battery is fully charged.
6) Since this is a battery maintainer and you will keep it connected with
vehicle battery for a long time, do monitor monthly. Follow the battery
manufacturer's instructions for adding distilled water if applicable.
7) Following is the charger's technical specification:
AC Input
DC Output
Start Voltage
Housing Protection
Battery Type
Accessories Included
Ambient Temperature

CONNECTING TO THE BATTERY

1) Identify polarity of battery posts. The positive battery terminal is
typically marked by these letters or symbol (POS,P,+). The negative
battery terminal is typically marked by these letters or symbol (NEG,N,-).
2) Do not make any connections to the carburetor, fuel lines, or thin
metal parts.
3) Identify if you have a negative or positive grounded vehicle. This can
be done by identifying which battery post (NEG or POS) is connected to
the chassis.
4) For a negative grounded vehicle (most common): connect the RED
POSITIVE clamp / ring connector first to the positive battery terminal,
then connect the BLACK NEGATIV clamp / ring connector to the negative
battery terminal or vehicle chassis.
5) For a positive grounded vehicle (very uncommon): connect the BLACK
NEGATIV clamp / ring connector first to the negative battery terminal,
then connect the RED POSITIVE clamp / ring connector to the positive
battery terminal or vehicle chassis.
6) When disconnecting, disconnect in the reverse sequence, removing
the negative first (or positive first for positive ground systems).
220-240VAC, 50-60Hz, 0.5A
12VDC, 1A;
6VDC, 1A
> 1V
IP54
All Types of 6V and 12V Lead-acid
Batteries
Clamp Connectors, Ring Connectors
0℃ ~ +40℃
3