Operation
NOTE!
The compressor is designed for interval operation.
For trouble-free operation, the duty cycle S3-25 must
not be exceeded. If you e.g. 10 min. paint, the com-
pressor must not last longer than 2.5 min. to run.
ATTENTION!
- The connected duck air tools must be designed for
the outlet pressure of the compressor or operated
with pressure reducer.
Use ear protection!
Use safety goggles!
Wear respiratory protection when working
with dust or fog!
Use safety shoes!
Wear protective cothing!
DANGER!
The device may only be operated in a technically
perfect condition. Any faults must be eliminated
immediately.
Check the safety valve for proper function by pulling
the ring outwards and thereby opening the safety
valve (The
Pressure vessel must be under pressure).
Motor protection
The compressor is equipped with a motor protection
that automatically cuts off the power supply in case of
overload. If the motor protection triggers a forced shut-
down disconnect the compressor from the mains and
wait 5 minutes before restarting the compressor. If the
compressor does not start yet, wait another 3 minutes. If
the compressor does not start, contact an authorized
service center.
10

7.1 Assembly and installation

Mount the suction cups as shown in fig. 4.
5
Fig. 4: Mount the suction cups
Design the working space around the compressor ac-
cording to local safety regulations. The working space
for operation, maintenance and repair must not be re-
stricted.
Requirements for the installation site:
- Dry, dust-free,
- Cool, well ventilated, frost protected,
- Flat, firm ground
NOTE!
Always place the compressor at least 50 cm away
from any obstruction that could obstruct the flow of
air and thus cooling.
ATTTENTION!
- Secure the compressor against tipping over and
slipping.
- Ensure easy accessibility of controls and safety de-
vices.
Install the compressor in a location the size of which
allows the room temperature to be maintained at a maxi-
mum of 40 ° C while the compressor is operating.
Use the compressor only on firm, level ground. If it can
not be avoided, a possible incline must not exceed 15 °.
AIRBOY | Version 1.07