- ページ 4
無線アクセスポイント HiB iCLASS SE R90のPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。HiB iCLASS SE R90 7 ページ。
iCLASS SE
2
Wiring
P1
7
Terminal
Description
P1-1
Beeper Input
P1-2
LED Input (GRN)
P1-3
Ground (RTN)
P1-4
+VDC
P1-5
Unused
P1-6
LED Input (RED)
P1-7
Hold Input
Note: Terminal IDs have changed from the previous generation of R90 Readers. When replacing an existing R90A reader, the connector wiring must
be modified to that shown in the table prior to installing the R90E reader.
*
Tamper Output - When activated, output synchronizes to ground (default).
**
Dependent upon reader configuration. See the HTOG for Wiegand and Clock-in-Data configurations.
R90
P2
1 7
1
Terminal
P2-1
P2-2
P2-3
P2-4
P2-5
P2-6
P2-7
P1
P2
7
1 7
1
Description
GPIO4 (RS485-Y / TXA)
GPIO3 (RS485-Z / TXB)
**
Wiegand Data 0 / Data
**
Wiegand Data 1 / Clock
*
Open Collector Output / Tamper
GPIO2 (RS232-R / RS485-RXB)
GPIO1 (RS232-T / RS485-RXA)
PLT-01051, A.3
ATTENTION
Observe precautions for handling