- ページ 6
サーモスタット Celect CC852KITのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Celect CC852KIT 10 ページ。 Rf programmable thermostat
3. Receiver Address Accessing
1. Pull out the door by using a screwdriver.
2. Set the RF address. The receiver RF address must
match the transmitter RF address.
3. Close and press the door until hearing a "click" sound.
Warning: Disconnect from supply before
opening the door.
Upper Position: 1
lower Position: 0
e.g
Address: 11110011
low position.
5
H. Internal Setting Mode:
Hold
and
key to enter internal setting.
Press
or
to switch items and adjust value.
Press
for item selection and confirm.
Press
to exit the setting.
System Mode:
HE – Heat mode (default)
CL – Cool mode
Display Unit:
12 – 12 hour display unit
24 – 24 hour display unit (default)
Minimum Off Delay:
Sd – Short delay (default)
Ld – Long delay - 5 min.
Temperature Calibration:
-3 - 3℃.
0℃(default)
RF Address
00000000 – 11111111 (default)
14