防虫機器 Agrimate AF 4000NKのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Agrimate AF 4000NK 16 ページ。 Vehicle mount type
D. You can hear the air pump operating but the machine will not work.
Cause
1. Defective igniter or
defective terminal
wires.
2. Defective spark
plug. Insufficient
spark to start the
machine
3. Too much gas in
the carburetor
has occurred
when there is a
knocking sound is
coming from the
carburetor.
4. Thermal pipe coil
damage
5. Insufficient battery
charge.
E. When you can see large sparks in the carburetor then the machine is not working properly.
Cause
1.Damaged Petal
valve
2. Uneven gap
between the petal
valve and the petal
valve plate.
(That means the ignition is not working)
How to Check
It's normal if a spark occurs when you
hold the spark plug 3-4min from the
ignition terminal.
Make sure the + terminal has firm
contract with the ground wire.
Normal when spark occurs when
start button is pushed. The gap of
the spark plug is normal when it is
3-4mm. Check to see if carbon has
built up on the spark plug.
Machine isn't working correctly if
when you take the carburetor cover
off and cover is very wet.
Check damage with a strong
flashlight.
Insufficient charge if the sound of the
machine is weak.
How to Check
To check the petal valve
you must take a apart the
carburetor, then replace the
petal valve.
Check the gap by taking apart the
carburetor.
6
Solution
• Replace the igniter
• Make sure terminal
contract is firm.
• Replace the spark plug
• Maintain 3mm gap.
• Remove carbon from the
spark plug
• Wipe the gasoline off the
carburetor completely.
• Shut the fuel nozzle
and wait until you hear
a cough sound while
operating the machine,
then press the start
button.
Have the thermal pipe coil
repaired.
Replace recharge the battery.
Solution
Make sure petal plate is not
moved when removing the
valve.
Replace the petal valve or