- ページ 16

計測機器 DynaQuip WaterCop ClassicのPDF オーナーズマニュアル&インストレーションマニュアルをオンラインで閲覧またはダウンロードできます。DynaQuip WaterCop Classic 20 ページ。

8 . Install compression nuts and sleeves to each tube end .
9 . Shift tube ends to install WaterCop® valve in line .
10 . Position the unit and tighten compression nuts . Hold the fitting with one wrench
while tightening the nut with the other . Tighten both nuts .
11 . Plug unit into a proper power source and turn valve to open position (OPEN
button/green light) .
12 . Unplug unit, turn water back on and carefully check for leaks .
13 . Tighten fittings if needed to stop any leaks .
14 . Plug unit back into power source . Installation is complete .

Solder Fittings

An alternative method is to solder the unit into the water line . This method requires a
considerably higher skill level to accomplish the installation properly and safely . If you
are not skilled in this area, it is strongly recommended that you contact a professional
plumber to do this type of installation .
Electrical Connections
The WaterCop® is supplied with a power adapter (20' cord) to be plugged into a
120 VAC power source . It is recommended that the WaterCop® not be plugged into
an extension cord .
Review "Specification" current and power requirements as not to overload the circuit
supplying power .
As with all valuable electronic items; we recommend plugging the WaterCop®
Actuator into a surge protector.
Warnings and Precautions
WARNING:
loads. Do no attempt to use the unit as a step. This will cause damage to the
unit and could cause personal injury. Do not store highly flammable items
such as oily rags or other combustibles near your WaterCop.®
CAUTION!
installing or servicing the system. Failure to do so could result in
personal injury.
CAUTION!
unit or tightening fittings. Apply wrench to flats on the valve body to
tighten fittings.
16
The motorized drive unit case is not capable of supporting any
It is recommended that eye protection be worn while
Do not use the case as leverage when mounting this