タイマー Autonics LE4SAのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Autonics LE4SA 17 ページ。 Din w48xh48mm digital backlight lcd timer
Autonics LE4SA にも: インストラクション (18 ページ)
● One-shot output time setting
[Figure2]
※ Factory default
● Time progress UP/DOWN setting
[Figure3]
※ Factory default
● The minimum input signal setting (LE4S only)
[Figure4]
※ Factory default
● Output contact setting (LE4SA only)
[Figure5]
※ Factory default
When output operation mode ON Delay 2[
1) In function setting mode, if it enters into One-shot output time setting mode as shown in
the [Figure 2], the last digit will flash.
2) Set One-shot output time using
3) Pressing
to complete one-shot output time setting and move to the next mode.
4) If pressing
for 3 sec in any function setting mode, it will return to Run mode.
1) In function setting mode, if it advances to UP/DOWN setting mode, the characters will be
displayed as shown in the [Figure 3].
2) Select UP (▲), DN (▼) using
3) Press
to complete UP/DOWN setting and move to the next mode.
4) If pressing
for 3sec in any function setting mode, it will return to Run mode.
RESET, START and INHIBIT.
1) In function setting mode, if it enters into input signal setting mode, the characters will be
displayed as shown in the [Figure 4].
2) Select 1ms or 20ms using
3) Press
to complete input signal width and move to the next mode.
4) If Pressing
over 3 sec in any function setting mode, it will return to Run mode.
1) In function setting mode, if it enters into output contact setting mode, the characters will be
displayed as shown in the [Figure 5].
2) Select time limit 1c+instant limit 1c or time limit 2c using
(refer to LE4SA Series, Connections section for output contact connections)
3) Press
to complete output contact setting and move to the next mode.
4) If pressing
for 3 sec in any function setting, it will return to Run mode.
※ Except for Star-Delta, Twin and Twin 1 modes (2C is set automatically)
※ If pressing
in Run mode, output contact setting value will be displayed.
(if no key is pressed over 3 sec, it will enter into function setting mode.)
LCD Display Timer
],
ONd2
and
. (setting range: 0.01s to 99.99s)
,
.
,
.
,
.
N-31
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
(N)
Timers
(O)
Digital
Panel Meters
(P)
Indicators
(Q)
Converters
(R)
Digital
Display Units
(S)
Sensor
Controllers
(T)
Switching
Mode Power
Supplies
(U)
Recorders
(V)
HMIs
(W)
Panel PC
(X)
Field Network
Devices