- ページ 11

アンプ Autonomic Mirage m-401eのPDF マニュアルをオンラインで閲覧またはダウンロードできます。Autonomic Mirage m-401e 13 ページ。 Multi-zone digital amplifier

Multiple Amplifi er (Continued)
In large installations where multiple M-401e
amplifi ers are required, Ethernet conveys
amplifi er control, and link to other Media
sources if connected to the Home network
Router or Switch. Ensure all amplifi ers
using same the amp ID in the stack.

Controller Wiring

The M-401e is packed with control options:
• USB:
Used for firmware update.
• ETHERNET:
Two 100BaseT connections to a home network or to daisy chain other amplifiers.
• CONTROLLERS:
Conveys +12VDC, IR and data between the M-401e and KP-6 keypad controllers,
connected using CAT5 cables.
• BUS RUN:
For future use.
• TRIGGERS:
+12VDC 100mA trigger output when a zone is on.

Ethernet Protocol

The Ethernet port provides data acquisition and control of the Mirage amplifi ers by a home
automation system, or PC Via TCP port 17037.
Command Structure: <command> <zone> <data> <line feed>
Please see online support documents under the amplifi ers section.
Command
01
02
03
04
05
06
07
09
0B
0C
0D
11
12
14
1C
1D
26
The source equipment audio inputs must
be plugged into the fi rst amplifi er where
they are buffered and sent to the next
amplifi er in the stack. The maximum
recommended expansion is 24 units.
Description
Standby
Mute
Source Selection
Volume
Bass
Treble
Balance
Send All parameters
Cause key press on Keypad
Amplifi er features
Maximum Volume Limit
Volume Up
Volume Down
Request Device information
Zone Name
Preamplifi er Volume Mode
Volume BCD format
* Fig 2 shows a stack of M-401e with Source
connections to fi rst amplifi er where they are
converted to Digital audio, buffered and sent
to the next amplifi er in the stack. Use good
quality Coax Digital Shielded RCA cables for
the interconnection, cables should be no
more than 3 meters or 10 feet. The maximum
recommended expansion is twelve units. This
chaining of Ethernet is an option but a direct
connection to the router is the best option.
Zone
Amplifi ers are encoded with up to 96 zones.
The zone byte is used for checking if the
command is applicable to the device receiving
the command and if so, for optionally selecting
a sub-device, e.g. a bank or part of a device.
All Zones are addressed using FF. The lower 5
bits of the zone byte represent the zone 0 – 31.
Selection:
• 00000 bin = 00 (hex) = zone 0
• 00001 bin = 01 (hex) = zone 1
• 01010 bin = 0A (hex) = zone 10
• 11111 bin = 1F (hex) = zone 31
Examples:
Addressing a zone 10 amplifi er:
Binary 000-01010 or 0A hex
Send ASCII "0A"
Addressing all Zone amp & preamplifi ers:
FF hex Send ASCII "FF"
11
FIGURE 3