Performance

Viscosity Calibrated Range
Viscosity Accuracy
Viscosity Repeatability
Density Calibrated Range
Density Accuracy
Density Repeatability

Temperature specification

Process
Ambient
Integral temperature sensor
Technology
Accuracy
6
Micro Motion 7829 Visconic Viscosity Meter
0.5 to 100 cP
10 to 1000 cP
100 to 12500 cP (long-stem version only)
±1% span (±0.2 cP up to 10 cP)
±0.5% of reading
0.6 to 1.25 g/cc
±0.001 g/cc
±0.0001 g/cc
Short-stem version
Long-stem version
100 Ohms RTD (4 wire)
PT100 BS1904 Class B, DIN 43760 Class B
3
38 to 78 lb/ft
3
±0.0624 lb/ft
3
±0.0062 lb/ft
–40 °F to +392 °F (–40 °C to +200 °C)
–40 °F to +302 °F (–40 °C to +150 °C)
–40 °F to +185 °F (–40 °C to +85 °C)