浄水器 High Tech Gio-Bella HTH 888のPDF マニュアルをオンラインで閲覧またはダウンロードできます。High Tech Gio-Bella HTH 888 16 ページ。 Point of use residential water alkalizer for drinking and cooking
o Carbon Block
o Combo carbon and scale inhibiter
o Fluoride/arsenic
cut the hose at the location where the filter
is to be placed and fasten hose from
diverter onto to the filter end marked "in", or
"input from faucet." Once again, secure
hose with a clamp. With sharp scissors, cut
nd
a 2
piece of hose sufficient in length to
reach from the "output" side of the prefilter,
to the "water input" port under the Gio-
Bella. Secure each of these connections
with clamps.
If not installing a Bluestone
•
Group prefilter, hose length
should reach from the diverter
valve fitting to the input fitting
located under the Gio-Bella.
Secure this connection with a clamp.
The last connection will be from the
•
"ACID OUTPUT" port under the Gio-Bella.
Simply cut a sufficient length of hose to
reach from the Gio-Bella, back to the sink
drain. Allow some extra length in the
event acid water is to be collected for
external or plant use. There is no need for
a clamp at this location since it will not be
pressurized.
Finally, attach the flexible dispensing hose
•
to the rotating plastic turret on top of the
Gio-Bella. Rotate threaded end clockwise,
until finger-tight.
6
Cutting hose to
length at optional
prefilter
Acid output,
bottom right
Installing Gio-Bella
flexhose