- ページ 8

アンプ Galil DMC-30011のPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。Galil DMC-30011 17 ページ。 Dmc-3xx1 series integrated amplifier

Wiring the DMC-3xx12
The basic wiring for a DMC-3xx12 is shown in Figure 6. The disconnect switch or circuit breaker for
AC power must be installed in a location that meets the following requirements:
Placed in close proximity to the equipment, within easy reach of the operator, and must not
block the installation of the controller
Marked as the disconnect device for the equipment
Connectors for DMC-3xx12
POWER
A,B,C,D: 4-pin Motor
Power Connectors
On Board Connector
2-pin MATE-N-LOK
MOLEX# 39-31-0020
4-pin MATE-N-LOK
MOLEX# 39-31-0040
For mating connectors see

Power Connector

Pin Number
Connection
1
DC Power Supply Ground
2
+VS (DC Power)

Motor Connector

1
Phase C
2
Phase B (N/C for Bushed Motors)
3
No Connect
4
Phase A
Terminal Pins
MOLEX#44476-3112
MOLEX#44476-3112
http://www.molex.com/