Galil DMC-30011 Manual de instalação - Página 8
Procurar online ou descarregar pdf Manual de instalação para Amplificador Galil DMC-30011. Galil DMC-30011 17 páginas. Dmc-3xx1 series integrated amplifier
- 1. Amplifier Installation
- 1. Chapter 1 Overview
- 2. Using this Manual
- 2. Chapter 2 Installation
- 2. Operating Environment
- 2. Mounting Location
- 2. Unpacking the Controller
- 2. Mounting the Controller
- 2. Powering the Controller
- 2. Power Connector
- 2. Motor Connector
- 2. Communication Connection
- 2. Additional Wiring
- 2. Ethernet Connection
- 3. Appendix: Specifications
- 3. Fault Information
Wiring the DMC-3xx12
The basic wiring for a DMC-3xx12 is shown in Figure 6. The disconnect switch or circuit breaker for
AC power must be installed in a location that meets the following requirements:
Placed in close proximity to the equipment, within easy reach of the operator, and must not
•
block the installation of the controller
Marked as the disconnect device for the equipment
•
Connectors for DMC-3xx12
POWER
A,B,C,D: 4-pin Motor
Power Connectors
On Board Connector
2-pin MATE-N-LOK
MOLEX# 39-31-0020
4-pin MATE-N-LOK
MOLEX# 39-31-0040
For mating connectors see
Power Connector
Pin Number
Connection
1
DC Power Supply Ground
2
+VS (DC Power)
Motor Connector
1
Phase C
2
Phase B (N/C for Bushed Motors)
3
No Connect
4
Phase A
Terminal Pins
MOLEX#44476-3112
MOLEX#44476-3112
http://www.molex.com/