the support bracket.
4. Disconnect the plastic power connector between the power
supply and wire harness.
5. Remove the two screws that secure the power supply to
the metal base.
6. Install the new ozone module by reversing the above steps.
4D. Troubleshooting
Knowledge of electrical applications is required for troubleshooting.
Contact a certifi ed electrician if you are unsure of your ability to
service the equipment. Improper servicing will void generator
warranty.
Symptom: "LED Indicator" not lit when pool system
4D-1
is on.
1. No power to the ozone generator from the power
source:
a. Check circuit breaker at the power distribution box.
b. Check for loose connections or wiring breaks from
the power distribution box to the generator.
c. Fuse in the unit has blown and needs to be replaced.
Fuse is an AGC-1 (1/4" x 1.25"long glass fuse).
2. G.F.C.I. has tripped.
a. Check power cord and reset G.F.C.I.
Symptom: LED Indicator has turned red.
4D-2
a. This means that the power supply of that specifi c
ozone module is no longer drawing power and needs
to be replaced. Refer to section 4C for instructions on
how to replace the corresponding ozone module.
Note: It is normal for the LED indicators to shine
red for several seconds as the system powers up.
As long as they turn back to green several seconds
after startup.
Symptom: Flowmeter not indicating fl ow.
4D-3
1. Injector not supplying adequate suction.
a. Check pump, fi lters, and skimmers to ensure water is
fl owing through injector.
b. Ensure that there is no debris clogged inside the injector. A
Union fi tting is installed to simplify the removal of the injector.
2. Tubing is impaired.
a. Check for kinks or clogs.
b. Check for cracks or cuts.
c. Check connections.
d. Check that the check valve is installed with the arrow
pointing towards the injector.
e. Be sure that the check valve has not become fouled
with debris. Disconnect the ozone tubing from the
injector. With the pump running, test the end of the
injector with your thumb, and feel for suction. If there
is suffi cient suction without the check valve, replace
the check valve with a new one.
Symptom: Flow Control Assembly is Clogged.
4D-4
Clean or replace fl ow control assembly.
Symptom: Ozone tubing becomes yellow/brown and
4D-5
brittle.
a. The high concentration of ozone created by the CoPi-
lot family of corona discharge ozone generators, as