- ページ 12
計測機器 Decagon Devices DS-2のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Decagon Devices DS-2 20 ページ。 Sonic anemometer
DS-2
3 CONNECTING THE ANEMOMETER
tin the wires, and wire it directly into the data logger. This has
the advantage of creating a direct connection with no chance of the
sensor becoming unplugged; however, it then cannot be easily used
in the future with a Decagon data logger.
The other option is to obtain an adapter cable from Decagon. The
3-wire sensor adapter cable has a connector for the sensor jack on
one end, and three wires on the other end for connection to a data
logger (this is referred to as a "pigtail adapter"). Both the stripped
and tinned adapter cable wires have the same termination as Figure
3; the white wire is excitation, red is data output, and the bare wire
is ground.
Note: Be extra careful to secure your stereo to the pigtail adapter
connections to ensure that your sensors do not become disconnected
during use.
9