水ポンプ Bristan ST PUMP20TNのPDF 据付・操作・メンテナンス説明書をオンラインで閲覧またはダウンロードできます。Bristan ST PUMP20TN 20 ページ。 Standard 1.5/2.0 bar twin/single ended shower pump

3 PUMP CONNECTIONS

z
z
z
z
3.11 Hose to pump: The pump inlet and outlet ports have moulded fittings which
are specifically designed for connection to the G ¾ female running nuts on the
flexible hoses. The hose end running nut is fitted with a rubber sealing washer
which is held captive within the nut assembly. Locate the hose into position and
screw the nut fully onto the fitting by hand. Finally nip tight with pliers (4/5 Nm)
for a water tight seal (do not overtighten).
Fig. 6
Do not use stainless steel, chrome or nickel plated pipe with
the flexible hose push-in plumbing connections.
Do not introduce solder flux into the joint or surrounding area
as connectors will be attacked and may fail.
All solder joints should be completed and flux residues removed
before final connection to push-in connections, on the flexible
hose.
Do not allow contact with oil or cellulose based paints, paint
thinners or strippers, acid based descalents or aggressive
cleaning agents.
Never operate pump with inlet and/or outlet isolating valves in
the closed position. Damage will occur!
G ¾ running nut
assembly
Port fitting
Flexible hose
- 9 -
Rubber sealing
washer (captive in
nut assembly)
Cont ...