- ページ 7

バスルーム設備 decina Luna 1000 SB1000C3TのPDF インストレーション・マニュアルをオンラインで閲覧またはダウンロードできます。decina Luna 1000 SB1000C3T 11 ページ。 Shower bases & acrylic shower wall

6mm min
Once sheeting is completed, use a flexible waterproof sealant (not supplied) to seal
the gap between the shower base tile bead and the wet area sheet.
FOR STEEL STUD WALL FRAMES WITH ACRYLIC SHOWER WALL
APPLICATIONS - SEE BELOW
NOTE: As a steel wall stud should not be cut, it
is necessary to build out the wall level to clear
the shower base tile bead thickness.
A suitable wet area sheet product of no less
than 12mm thickness is required to achieve
the desired level. Use of either a 13mm Wet
Area Plasterboard or 12mm Wet Area Fibre
Cement sheet is advised.
Install the chosen 12 or 13mm wet area sheet
product bottom edge at least 6mm above
the tile bead (as per relevant manufacturer's
instructions).
Once sheeting is completed, use a flexible waterproof sealant (not supplied) to
seal the gap between the shower base tile bead and the wet area sheet.
S H OWE R IN STA LLATI O N G U I D E
12
6mm min
© Copyright Decina Bathroomware Pty Ltd 2016
11
ACRYLIC SHOWER WALL LINER
INSTALLATION
DRILLING TAP HOLES IN ACRYLIC WALL
Have a qualified tradesperson install the shower
fittings. Mark the position of the holes for the fittings
on acrylic shower wall.
Large holes must be drilled with a fine tooth hole saw.
Holes should be drilled from the outside show face only
Ensure all final hole sizes have at least a 2mm
clearance around tap fittings for expansion.
ATTACHING THE ACRYLIC SHOWER WALL
Positioning shower wall
Trial position the shower wall against the shower recess, ensuring it fits squarely
into the recess corner and shower base.
Tape the corners with masking tape to hold the liner in position.
Use a soft pencil to mark around the edges of the shower wall before removing.
© Copyright Decina Bathroomware Pty Ltd 2016
2mm min
clearance
13
SH OW ER I NS TA LLATI O N G UI DE