5.
GROUND CHASSIS (CONTINUED)
Step 1:
Use a wire-stripping tool to remove approximately
0.4- in (10.9 mm) of the covering from the end of
the grounding wire.
Step 2:
Insert the stripped end of the grounding wire into
the open end of the grounding lug.
Step 3:
Crimp the grounding wire in the barrel of the
grounding lug. Verify that the ground wire is
securely attached to the ground lug by holding the
ground lug and gently pulling on the ground wire.
Step 4:
Prepare the other end of the grounding wire and
connect it to an appropriate grounding point at the
site to ensure adequate earth ground.
6.
FIBER CONNECTIONS
Using an MTP®-LC APC harness cable:
• Connect the harness cables' MTP® connector to the
OIM MTP connector
• Remove the protective plastic covers and connect the
(3) LC APC connection fibers to the FMU EDGE™ module
LC APC connections. See Figure 7.
ATTENTION! Take note of the fiber numbering (i.e., 1/2/3).
7.
EXPANDER CONNECTIONS TO HEU
RF expander connections between the OIU and HEU are
performed using the ERFC cable (included in HEU order)
and are described in the HEU quick installation sheet
(CMA-267-AEN) provided with the unit. See Figure 8 for
general view of connections.