- ページ 9

屋外暖炉 Empire OLI24NのPDF 取付説明書および取扱説明書をオンラインで閲覧またはダウンロードできます。Empire OLI24N 20 ページ。 Ventless decorative appliance intermittent ignition

Empire OLI24N 取付説明書および取扱説明書
Minimum Dimensions For Solid Fuel Burning Fireplaces
Model
A
OLI-24
28"
OLI-30
32"
The dimensions shown and defined in the fireplace instructions are
minimum clearances to maintain in installing this heater. Left and
right clearances are determined when facing the front of the heater.
Glass Doors
Make sure that glass doors are open during all operations of the
appliance. The opening of the glass door frame should be the
dimension used for the minimum front opening of the firebox.
Follow these instructions to ensure safe installation.
Failure to follow instructions exactly can create a fire hazard.
Model
Input BTU/Hr Maximum
Input BTU/Hr Minimum
Orifice
Air Shutter Opening
Model
OLI24
OLI30

BEFORE FULLy INSTALLING THE APPLIANCE

You must secure the gas burner to the firebox floor. If not, the
entire unit may move when you adjust the controls.
1. Center the gas burner in the fireplace or firebox. The burner
must clear the firebox screen.
2. An anchor hole is provided in the two bottom side burner. After
centering the burner correctly, mark the hole positions on the
firebox floor. Drill two (2) 5/32" diameter holes approximately
1-1/2" deep for masonry screws or 1/8" hole for sheet metal
screws.
3. Anchor the burner to the firebox floor using the screws pro-
vided.
37139-8-1219

CLEARANCES

B
C
15
9 /16
"
34
5 /16
"
24
15
9 /16
"
38
5 /16
"
24

SPECIFICATIONS

OLI24P
36,000
28,000
#50
FULL OPEN
D
3 /16
"
3 /16
"
OLI24N
36,000
27,000
#31
1/8" OPEN
CONVERSION KITS
Propane
32001
32003
OLI30P
40,000
28,000
#49
FULL OPEN
1/8" OPEN
Natural
32002
32004
ANCHOR SCREWS
Figure 1
OLI30N
36,000
27,000
#31
Page 9