ENGLISH
4.3
Change Fill Time for Safety Lockout
Mode
To change the pre-set factory Fill time, turn off the
power to the control box, open it up, and cut one or both
jumpers on the circuit board.
WARNING
Turn off the power to the control box before starting
this procedure. Failure to comply may cause a shock
hazard, resulting in severe personal injury or death.
1.
Shut off the power to the control box.
2.
Take the upper cover plate off the control box by
removing the three (3) screws that secure it.
3.
Locate the jumpers at the top left of the circuit
board. See Figure 11.
4.
Modify the Fill time by cutting Jumpers A and/or
B, as shown in Table 3, below.
Table 3. Fill Safety Lockout Mode Settings
Jumper(s)
Fill Time Period
Factory Default
20 minute Fill before Lockout
Cut Either A or B
40 minute Fill before Lockout
Cut Both A and B
60 minute Fill before Lockout
NOTE Cutting the S-1 Jumper will disable the Safety-
Lockout function.
5.
Replace the top cover plate, being careful to align
the LED lights with the plastic lenses in the cover.
Install the three (3) screws. Do not tighten or you
6.
will damage the plastic mounts.
7.
Restore the power to the control box. The new
timing changes will take effect.
NOTE If you change the Fill Safety Lockout Mode
settings without turning the power off in
advance and on afterwards, you will need to
cycle the power from OFF to ON for the new
timing changes to take effect.
Jandy Pro Series Levolor
II Electronic Water Leveler
®
Models K-2100
Lockout
Jumpers
Figure 11. Safety Lockout Jumpers
|
Installation and Operation Manual
S 1
A
B