Safety Instructions
- Please open and check whether break or not for transport once receive this fixture, if yes, not use
it and contact dealer or manufacture as soon as possible.
- The Max applicable temperature for the light is 40°C. Do not use the light under or above the
temperature. ta=40
- The fixture is applicable for many occasions, it should keep clean, and avoid long use in overheating
or dusty environment. To prevent the fixture from the chemical liquid .
- User must be careful of fire, heat, electric and fall-off that make heavy or fatal injury. Please read
this user manual carefully before power on and installation, following safety and operation instruc-
tion in it. If still have any questions, please contact dealer or manufacture.
- User must following this user manual, do not open fixture by yourself, if any problems, please
contact professional technician, maintenance should by technician.
- Do not power on or start the fixture before installation, please stop after working more than 8
hours, which will longer use life.
- Fixed installation, do not by strong shocks.
- The minimum distance between light and the illuminated surface must be more than 1 meter.
- Never look directly into the light source to avoid hurt to eyes (especially epileptics)!
- When dustproof glass at light output breaks, cracks or other visible damage, user should replace
with new glass to continue to use.
Installation
- When install this equipment please make sure there's no flammable surfaces (decorated things,
etc) and minimum distance of 0.5M from the equipment to the flammable.
- The installation of the effect has to be built and constructed in a way that it can hold 10 times the
weight and without any harming deformation.
- The installation must always be secured with a secondary safety attachment, e.g. an appropriate
safety rope. Never stand directly below the device when mounting, removing or servicing the fixture.
Technical Specifications
Input voltage: AC127V, 60Hz
Fuse: BGDP ¢5x20mm 250VAC T2A
Total power: 30W
Light source: R:250mw/638nm,G:100mw/532nm,B:500mw/445nm
Control mode: Auto/Sound/DMX512
Channels:16CH
Scanning system: 10Kpps Scanner, ±15º
Surface temp: Tb=40ºC ( this data testing when the environment temp is 30ºC)
Working temp: 10ºC--65ºC
Modulation: TTL
N.W: 4.0Kg
G.W: 4.5Kg
Inner packing size: 36X30X16cm
Outer packing size: 70X38X32cm(4pcs/ctn)
w w w . a l i e n p r o . c o m . m x
2
Ringing
1 Mounting bracket
2 Handle
A) The ambient temperature range is -25°C--45°C, must never be exceeded.
B) The installation of the projector has to be built and constructed in a way that it can hold 10 times
the weight for 1 hour without any harming deformation.
C) When rigging, derigging or servicing the fixture staying in the area below the installation place, on
bridges,under high working places and other endangered areas is forbidden.
D) The operator has to make sure that safety-relating and machine-technical installations are
approved by an expert before taking into operation for the first time and after changes before taking
into operation another time.
E) The operator has to make sure that safety-relating and machine-technical installations are
approved by a skilled person once a year.
F) Sure M8 screws on mounting bracket fixed middle hole ¢12.5mm of handle
Product size
Wiring diagram
w w w . a l i e n p r o . c o m . m x
7