- ページ 26

エアコン Fujitsu AB G18LVTB SeriesのPDF デザイン&テクニカル・マニュアルをオンラインで閲覧またはダウンロードできます。Fujitsu AB G18LVTB Series 45 ページ。

Fujitsu AB G18LVTB Series デザイン&テクニカル・マニュアル
1-4. Heater room temperature correction
Depending on the installed environment, the room temperature sensor may require a correction.
The settings may be changed as shown in the table below.
Setting Description
Standard
Lower control
Slightly warmer control
Warmer control
When using floor console installation, change the setting value to "1".
1-5. Auto restart
The following settings are also possible, depending on the operating conditions.
Setting Description
Yes
No
1-6. Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by Wired remote controller temperature
sensor.
Setting Description
No
Yes
If setting value is "00",
„
room temperature is controlled by the indoor unit temperature sensor.
If setting value is "01",
„
room temperature is controlled by either indoor unit temperature sensor or remote controller unit sensor.
1-7. Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
Setting Description
A
B
C
D
1-8. External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
Setting Description
Operation/Stop mode
(Setting forbidden)
Forced stop mode
(  . . .Factory setting)
Function Number
Setting Value
31
(  . . .Factory setting)
Function Number
Setting Value
40
(  . . .Factory setting)
Function Number
Setting Value
42
(  . . .Factory setting)
Function Number
Setting Value
44
(  . . .Factory setting)
Function Number
Setting Value
46
- (01 - 23) -
00
01
02
03
00
01
00
01
00
01
02
03
00
01
02