Permanent Connection

In the case of a permanent connection, it is necessary that you install
a double pole switch between the hob and the electricity supply
(mains), with a minimum gap of 3 mm. between the switch contacts
and of a type suitable for the required load in compliance with the
current electric regulations.
The switch must not break the yellow and green earth cable at any
point.
Ensure that the hob supply cord does not come into contact with
surfaces with temperatures higher than 50 deg. C.
Replacement of the cable
The connection of the voltage cable to the appliance's terminal block
is of type "Y". This means that its replacement requires the specific
equipment of a technician.
In this case, only cable type H05RR-F must be used. The cable section
must be suitable to the voltage and the working temperature.
The yellow/green earth wire must be approximately 2 cm. longer than
the phase wires.

Wiring diagram

L
1
N
N
1. TAPS IGNITOR SWITCHES
2. IGNITOR UNIT
Electrical connections
1
220
240
2
3
4
0
5
2
21